50% of the causes why AC freezes and blows warm air is low AIR-FLOW, there are a few reasons that can cause this problem with central Air Conditioning system such as
Des Plaines, Illinois, United States – January 18, 2023 /MarketersMEDIA/ —
There are a few reasons why central air conditioning freeze during the peak of heat at the time need it, in this article, will explain the top 2 reasons why central AC freeze in summer when it is very hot and what things might be done to fix frozen AC.
- Air Flow
- Air Conditioners low in the refrigerant.
There are more than 2 reasons, but the above are the main causes for central air conditioning to freeze during summer.
Air Flow:
50% of the causes why AC freezes and blows warm air is low AIR-FLOW and there are a few reasons that can cause this problem with central Air Conditioning system:
- Dirty Air Filter
- Bad or weak blower motor
- Restricting supply or return vents
- Dirty AC evaporator coil
Dirty Air Filter & How to Fix Frozen Air Conditioning
Needs to replace air filter more often, if find home AC system frozen and have a very dirty air filter? 80% of the dirty air filter is the issue, need to replace air filter the right way, if can turn central AC off for a few hours or turn ON the fan only (No Cooling), this will help melt the ice from around AC evaporator coil which is restricting the air from passing through, after few hours start your AC and issue should be fixed.
Bad or Weak Blower Motor
If a furnace has a bad blower motor or the blower motor is weak then the furnace will blow less air to warm the evaporator coil, and ice starts to build up until it will block the evaporator coil or do other damage such as water leaks, in this case, if you live in the northern Chicago land area! feel free to contact Any Season & Cooling for blower motor repair.
Restricting in Supply or Return Vents / Duct.
If there is an air restriction in the supply or return duct, it will make furnace blower motor blow less air, less air flow will cause the evaporator temperature to drop down below 32F and the coil starts to build ice till it blocks the coil, make sure did not block any duct vent or for example place a couch or picture in front of the main duct return.
Dirty AC Evaporator Coil
Sometimes people do not use air filters and dirt and dust start moving inside HVAC duct system, and in summer time evaporator coil is wet, so dust and dirt stuck in the coil, and within a few years, the coils will be very dirty and start restricting a smooth air-flow which will cause the evaporator coil to start to get frozen during summer time and furnace start short cycle or open limit switch during wintertime.
For a dirty evaporator coil, customer need to contact licensed heating and air conditioning company to clean the coil, which can lead sometimes to a few hours of work.
Air Conditioners low in refrigerant
The second main reason for frozen air conditioning is that the AC system is low in refrigerant, in this case, need to contact a licensed HVAC contractor to recharge Air Conditioning with freon.
Any Season Heating & Cooling offers low-cost air-conditioning refrigerant recharge, call today and will be happy to assist.
Low-Cost Air-Conditioning Freon Recharge
Need AC freon recharge, Any Season Heating & Cooling can help in:
- R22 Refrigerant recharge (R-22 Freon)
- R410a Refrigerant recharge (R-410a Puron)
Recharging central AC system needs a licensed HVAC contractor, Any Season Heating & Cooling has R-22 Refrigerant & R410a refrigerant in stock at low cost compare to other Air Conditioning companies.
About Us: For more information, contact Any Season Heating & Cooling Company, a full service HVAC contractor serving the Chicago land area.
Contact Info:
Name: Adnan Grifat
Email: Send Email
Organization: Any Season Heating & Cooling Inc.
Address: 894 Parkview Ln, Des Plaines, IL 60016
Phone: (847) 766-9654
Website: https://anyseasonheatingcooling.com/
Video URL: https://www.youtube.com/watch?v=PYJRU5Ay9Cw
Release ID: 89088444
If you detect any issues, problems, or errors in this press release content, kindly contact error@releasecontact.com to notify us. We will respond and rectify the situation in the next 8 hours.